single core insulated wire
"
UL1672 escogen el cable forrado PVC aislado PVC del conductor para el cableado interno
UL1672 Single Conductor with Extruded Insulation,105℃, 300V, VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature: -40~105℃ Flame: VW-1, FT1, FT2 Oil ...
UL10455 escogen los cables aislados PVC del conductor para el cableado interno del equipo electrónico
UL10455 Single conductor using extruded non-integral jacket, 90 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:90℃ Flame: ...
UL10603 FRPE aislados escogen el cable del conductor, AWG flexible del cable eléctrico 26 - AWG 9
UL10603 Single Conductor with extruded FRPE insulation, 80 ℃, 600 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
UL3321 escogen el alambre flexible del cable del cable del conductor con el aislamiento sacado de XLPE
UL3321 Single Conductor with extruded XLPE insulation, 150 ℃, 600 V or 750V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V OR 750V Rated Temperature: 150℃ Flame: VW-1, FT1, FT2 ...
Alambre del conductor del aislamiento de UL3820 XLPE el solo, dobla AWG del cable eléctrico 30 - Kcmil 2000
UL3820 Single Conductor with extruded XLPE insulation, 125℃, 1000 V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 1000 V Rated Temperature: 125℃ Flame: VW-1, FT1, FT2 Voltage ...
UL1483 escogen el cable del conductor con el conductor de cobre estañado/desnudo no integral de la chaqueta
UL1483 Single conductor using extruded non-integral jacket, 105 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:105℃ Flame...
40 AWG - solo cable del conductor de 10 AWG con el aislamiento sacado UL10602 de FRPE
UL10602 Single Conductor with extruded FRPE insulation, 80 ℃, 300 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 300 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
Solo cable eléctrico del conductor UL10863 con el halógeno sacado del aislamiento de FRPE libremente
UL10863 Single Conductor with extruded FRPE insulation, 80 ℃, 1000 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 1000 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
UL10198 aislados PVC escogen el cable del conductor, cable flexible a prueba de calor
UL10198 Single Conductor with Extruded Insulation,105℃, 300V, VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature: -40~105℃ Flame: VW-1, FT1, FT2 Oil ...