gancho encima del alambre
El gancho del cobre del PVC UL21449 encima del alambre sólido/trenzó el conductor multi 2000V VW-1
UL21449 Multiple-Conductor Cable using Non-Integral Jacket 80℃, 2000V VW-1 Construction Conductor : Solid or Stranded Insulation: PVC, SRPVC, PP, PE Shield or Braid: Optional Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:2000V Rated ...
Gancho flexible UL21411 encima del alambre, chaqueta multi 125℃ 300V VW-1 del cable XLPE del conductor
UL21411 Multiple-conductor cable using XLPE jacket, 125℃, 300V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Shield or Braid: Optional Jacket: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature:-40℃-125℃ ...
Gancho multi del conductor de Flexiable encima del alambre con color no integral de la aduana de la chaqueta UL2725
UL2725 Multiple-conductor cable using non-integral jacket, 80℃, 30V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC,PE, SRPVC, PP, Foam-PE Shield or Braid: Optional Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data ...
Cable eléctrico de la flexión UL2464 con el aislamiento multi del PVC/del PE/de SRPVC del conductor
UL2464 Multiple-conductor cable using non-integral jacket, 80 ℃, 300 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC,PE, SRPVC, PP, FOAM-PE Shield or Braid: Optional Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data ...
Gancho UL3271 encima del solo cable del conductor del alambre con AWG del aislamiento 30 de XLPE - kcmil 2000
UL3271 Single Conductor with extruded XLPE insulation, 125℃, 600 V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V Rated Temperature: 125℃ Flame: VW-1, FT1, FT2 Voltage ...
UL10703 escogen el gancho eléctrico del conductor encima del aislamiento 600V VW-1 del cable FRPE
UL10703 Single Conductor with extruded FRPE insulation, 80 ℃, 600 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
Temperatura alta resistente de FEP del aislamiento del solo del conductor aceite eléctrico del alambre UL1332
UL1332 Single Conductor with Covering, 200 ℃, 300 V , VW-1,80 ℃ Oil Construction Conductor :solid or stranded Insulation: FEP Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature:200℃ Flame: VW-1, FT1, FT2 Oil resistance: 80 ℃ Oil ...
UL1013 escogen el alambre eléctrico flexible del conductor con AWG del aislamiento 30 del PVC - Kcmil 2000
UL1013 Single Conductor with Extruded Insulation, 80 or 90 C,600 V OR 750V, VW-1,60 deg C or 80 deg C Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600V or 750v Rated Temperature:80 or ...
UL1569 escogen el conductor con el aislamiento sacado, 105 C, 300 V aceite o, de VW-1,60 DEG C o de 80 DEG C
UL1569 Single Conductor with Extruded Insulation, 105 C, 300V, VW-1,60C or 80C Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300v Rated Temperature: 105 OC Flame: VW-1, FT1, FT2 Oil ...