Solo cable del conductor
Aislamiento flexible coloreado del cable de cobre UL10533 FRPE del solo filamento multi de la base
UL10455 Single Conductor with extruded FRPE insulation, 90 ℃, 600 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V Rated Temperature: 90℃ Flame: VW-1, FT1, FT2 Voltage ...
UL10455 escogen los cables aislados PVC del conductor para el cableado interno del equipo electrónico
UL10455 Single conductor using extruded non-integral jacket, 90 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:90℃ Flame: ...
32- 16 el AWG UL10063 escoge el cable de cobre de la base con el aislamiento sacado del PE/de FRPE
UL10063 Single conductor with extruded insulation, 80 ℃, 300V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: Extruded PE or extruded FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300 V Rated Temperature:80℃ ...
El PVC aisló el cable flexible de la sola base UL1284 para 8AWG de conexión interno - 1000kcmil
UL1284 Single Conductor with Extruded Insulation, 105 ℃, 600 V , VW-1,60 ℃ or 80 ℃ Oil Construction Conductor :solid or stranded round Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600V Rated Temperature:105℃ Flame: VW-1, FT1, FT2 ...
Aislamiento flexible UL1185 del PVC del alambre de cobre de la sola base para la conexión de los dispositivos
UL1185 Single conductor using extruded non-integral jacket, 80 ℃, 300 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300 V Rated Temperature:80℃ Flame: ...
Solo cable UL1115 de la base del PVC, 1 alambre flexible y cable 30AWG - 16AWG del conductor
UL1115 Single conductor cable using non-integral jacket, 80 ℃, 300 V(insulation) ,600V(sheath) VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300 V...
El PVC flexible del alambre UL1283 de la sola base del conductor sola aisló 8 AWG - 2AWG
UL1283 Single Conductor with Extruded Insulation, 105 ℃, 600 V , VW-1,60 ℃ or 80 ℃ Oil Construction Conductor :solid or stranded, or braided conductor consisting of 40-20 AWG strands Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage...
Solo cable aislado PVC del conductor UL1028, AWG eléctrico del cable de alambre 22 - AWG 6
UL1028 Single Conductor with Extruded Insulation, 105 ℃, 600 V , VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600V Rated Temperature:105℃ Flame: VW-1, FT1, FT2 Oil ...
UL1032 escogen el aislamiento del PVC del cable del conductor con el sólido/el conductor trenzado
UL1032 Single Conductor with Extruded Insulation, 90 C,1000 V OR 1200V, VW-1,60 deg C or 80 deg C Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:1000V or 1200v Rated Temperature: 90 OC ...